View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0000536 | SpeedFan | Logging and charting | public | 2006-04-06 10:26 | 2007-10-10 12:47 |
Reporter | Mr Burns | Assigned To | alfredo | ||
Priority | normal | Severity | minor | Reproducibility | sometimes |
Status | resolved | Resolution | fixed | ||
Platform | Several (ALL?) | OS | Several | OS Version | Several |
Product Version | 4.28 | ||||
Summary | 0000536: Chart update causes access violation | ||||
Description | The charts are updated regularly. If temperatures are charted, fan speeds and voltages can be charted at update by hovering the mouse over the items in the pull-down menu. If you have three fans, and is charting a voltage number higher than the number of fans, then access violation will occur. | ||||
Steps To Reproduce | 0. Go to the charts 1. Select voltages 2. Start charting a voltage at the end of the list (or a temp. ). 3. Press the pull-down menu, but don't click any items. 4. Hold the mouse pinter over the fan-speeds items, but don't click the mouse. 5. At the next chart update there will be an access violation. | ||||
Additional Information | If there are 4 fan speeds, then selecting the fifth voltage/temperature will cause access violation. | ||||
Tags | No tags attached. | ||||
Motherboard Model | |||||
Video Card Model | NVidia 6200 TC | ||||