View Issue Details

IDProjectCategoryView StatusLast Update
0000370SpeedFanS.M.A.R.T.public2005-10-20 09:03
Reporterjack welch Assigned Toalfredo  
PrioritynormalSeverityfeatureReproducibilityalways
Status acknowledgedResolutionopen 
OSXPOS VersionSP1 
Product Version4.26 
Summary0000370: Lose temperature sensor when drives are in raid
DescriptionMy system fails to detect my hard drives when they are configured in RAID, but properly identifies and monitors the drives when they are in single SATA config.
Please help.

System is P4P800 with Seagate 300G SATA using Intel 82801ER SATA RAID controller

Speed Fan info:
Win9x:NO 64Bit:NO GiveIO:YES SpeedFan:YES
I/O properly initialized
Linked ISA BUS at $0290
Linked Intel 82801EB ICH5 SMBUS at $0400
Scanning ISA BUS at $0290...
Winbond W83627THF (ID=$90) found on ISA at $290
SuperIO Chip=Winbond W83627THF
Scanning Intel SMBus at $0400...
Unknown Winbond1=$5CA3 ID=$72 on SMBus at $2F
Unknown Winbond2=$9501 ID=$80 on SMBus at $2F
LM75 found on SMBus at $48
LM75 found on SMBus at $49
SMART Enabled for drive 0
Found IC35L180AVV207-1 (185.3GB)
SMART Enabled for drive 1
Found ST3300831A (300.1GB)
SMART Enabled for drive 3
Found IC35L180AVV207-1 (370.6GB)
End of detection
Error loading event -->
  CfgVersion=01.0001
  EventsVersion=01.0001
Loaded 0 events
TagsNo tags attached.
Motherboard Model
Video Card Model

Activities

alfredo

2005-10-20 09:03

manager   ~0001289

Unfortunately, there is very little I can do here. It's up to the HD driver answer the questions sent to him about S.M.A.R.T. status (which includes temperatures). When you configure two physical disks as a single logical one, it makes sense that this mapping will hide some hardware details.

Issue History

Date Modified Username Field Change
2005-10-20 02:04 jack welch New Issue
2005-10-20 09:03 alfredo Note Added: 0001289
2005-10-20 09:03 alfredo Severity minor => feature
2005-10-20 09:03 alfredo Status assigned => acknowledged
2005-10-20 09:03 alfredo Category Fan control => S.M.A.R.T.