View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0002089 | SpeedFan | Other | public | 2013-01-12 19:12 | 2013-03-17 16:26 |
Reporter | toad01 | Assigned To | alfredo | ||
Priority | normal | Severity | major | Reproducibility | always |
Status | assigned | Resolution | open | ||
Platform | Windows 8 Pro | ||||
Product Version | 4.47 | ||||
Summary | 0002089: Hangs at startup during sensor scanning when HDD(s) configured for Windows Storage Spaces | ||||
Description | Hangs during sensor scanning when 1 or more drive(s) are configured as a Windows 8 storage space. | ||||
Steps To Reproduce | Install SpeedFan and confirm correct operation with no drives configured as storage spaces. Exit program. Configure 1 or more drives as a storage space. Run SpeedFan. It will hang whilst sensor scanning (at ISA BUS stage). Delete all storage spaces. SpeedFan will then resume scanning and run correctly within a few minutes. | ||||
Additional Information | Have tried disabling ISA BUS access and also tried 4.48 Beta 6. | ||||
Tags | No tags attached. | ||||
Motherboard Model | HP N40L MicroServer | ||||
Video Card Model | |||||